Categories
Tutorials

Setting up a SIP provider on a Siemens HiPath 3000 PBX

Pre requirements:

  • HiPath 3000 V6.0 / V7.0 / V8.0 PBX
  • HXG 1500 card
  • Broadband Internet Access
  • A sip provider account (sipgate, qsc…)
  • HiPath 3000 Manager E
  • About 10 minutes time to set it up

You can view the tutorial online or download the PDF file here

First logon to the HXG 1500 and authenticate.

1

Now select the Explorers tab, hit Voice Gateway and Internet Telephony Service Provider.

2

Rightclick your Provider and hit Edit Internet Telephony Service Provider.

3

Tick the Enable Provider check box and select the Provider Identifier (Provider 1) and verify that all those settings are correct.

4

Now you have to setup your SIP logon, right click your created provider and hit Add Internet Telephony Station.

5

Enter your account details and press Apply.

6

Next you have to add an MSN which is the number that is sent out to your provider as caller number and used for inbound calls.
Right click MSN and hit Add MSN. Insert your number the destination that will ring when this number is dialled and press Apply.

7

Next right click Sip Parameters and select Edit Sip Parameters and change the maximum possible provider calls to a valid number (calculate about 80kbit/s for one SIP call).

8

This is the HXG part finished press the Save button on the bottom of the window and close the explorer.

9

On the Manager E, select Lines/Networking and hit IP Trunks. In there create the same amount of B-Channels that you have selected on the HXG card and select the same provider as in the network card and hit Add.

10

Under Routes rename the Trk Group 12 to your provider name.

11

Select the Routing Parameters tab and change the settings according to the picture.

12

Browse to least cost routing and activate it and set it to en-bloc sending.

13

Enter into the dial plan the sipgate testnumber as an extension -1XXXX and chose an available routing table (in my case 4) and create another rule for example for mobile calls starting with 01 to use that trunk enter 0C01Z and select a different routing table.

14

In the configured routing tables setup the route Sipgate (Your provider name) and create a Dial rule with the following settings for the internal destination starting with the dash (-)

For the mobile calls (external numbers) simply set the Dial rule format to A because it should send out every information you dial

16

That’s it happy testing and phoning 😉

21 replies on “Setting up a SIP provider on a Siemens HiPath 3000 PBX”

great explanation but what about the connection to the hg1500 card.
I have a dsl modem connected to my 24 ports switch and the hg1500 card is also connected to this switch.
Any help is appreciated.

Hello everyone,

Can someone help connect a HIpath 3500 with an HG1500 Card.
Currently i cant acess the HG card via IP.

Is there any software i can download for this purpose?

Regards,
Hugo Gentil

It’s appropriate time to make some plans for the future and it’s time to be happy. I’ve learn this publish and if I could I desire to suggest you few interesting things or advice. Maybe you could write subsequent articles relating to this article. I wish to read even more things approximately it!

magnificent put up, very informative. I wonder why the other
specialists of this sector do not understand this. You should
proceed your writing. I’m confident, you’ve a great readers’ base already!

Thanks for ones marvelous posting! I seriously enjoyed reading it, you can be a great author.I will make certain to bookmark your blog and definitely will come back from now
on. I want to encourage yourself to continue your great writing, have a nice
day!

Woah! I’m really digging the template/theme of this site.
It’s simple, yet effective. A lot of times it’s very
hard to get that “perfect balance” between usability and visual appearance.
I must say you’ve done a very good job with this. Also, the blog loads
super fast for me on Chrome. Outstanding Blog!

Oh my goodness! Awesome article dude! Many thanks, However I am experiencing difficulties with your RSS.
I don’t know the reason why I am unable to join it.
Is there anybody getting identical RSS problems? Anyone who knows the solution will you kindly respond?

Thanx!!

Hi,
we are using “Siemens hipath 3000 manager E pbx” with VOIP. Our VOIP calls are getting dropped every 45 min and this is happening for all VOIP calls.Can someone help us fix the issue?

regards
Srikanth

Leave a Reply